Everything on this page is generated when the site is built. The test counts come from the test files in this project, so they cannot be edited by hand. A count here is the number of test blocks written; a test written inside a loop runs more than once.
Tests and IBM sources, tool by tool
Tests are grouped to a tool by test file name. The IBM page behind each tool's rules is the list kept on that tool's page.
| TOOL | TESTS | IBM SOURCE BEHIND ITS RULES |
|---|---|---|
| COBOL debugger and structure | 168 | IBM Enterprise COBOL LR, MOVE: group moves IBM Enterprise COBOL LR, DIVIDE IBM Enterprise COBOL 6.4 PG, Handling errors when calling programs Db2 12 for z/OS, Writing an external procedure to return result sets to a distributed client CICS TS 5.6, Handling exception conditions Enterprise COBOL for z/OS 6.4 Language Reference: Reference format Enterprise COBOL for z/OS 6.4 Language Reference: PERFORM statement Enterprise COBOL for z/OS 6.4 Language Reference: Unconditional GO TO Enterprise COBOL for z/OS 6.4 Language Reference: Conditional GO TO Enterprise COBOL for z/OS 6.4 Language Reference: CALL statement Enterprise COBOL for z/OS 6.4 Programming Guide: DYNAM Enterprise COBOL for z/OS 6.4 Language Reference: SORT statement Enterprise COBOL for z/OS 6.4 Language Reference: FILE-CONTROL paragraph Db2 13 for z/OS SQL Reference: WHENEVER CICS TS 6.x application development reference: HANDLE CONDITION |
| REXX lab | 51 | IBM z/OS TSO/E REXX Reference: REXX instructions, built-in functions, parsing, numbers and arithmetic, expressions and operators |
| JCL checker | 44 | z/OS MVS JCL Reference (columns, continuation, DISP, PARM, DSN), as recorded in docs/FACTS.md RACF guide: JCL (security checks on JOB, USER, PROTECT) z/OS MVS JCL Reference: Status subparameter (data-set flow) z/OS MVS JCL Reference: COND parameter (z/OS 3.1) z/OS 3.2.0 DFSMSdfp Utilities: Guide to utility program functions (names of the DFSMS utilities) The site's own JCL reader (the one the JCL checker uses), as recorded in docs/FACTS.md |
| Db2 SQL explainer | 35 | Db2 13 for z/OS SQL Reference: SELECT INTO Db2 13 for z/OS Performance: Specifying isolation levels in SQL statements Db2 13 for z/OS Application Programming and SQL Guide: Executing SQL statements by using a row cursor Db2 for z/OS Codes: the SQLCODE pages cited on this site's SQLCODE pages |
| DFSORT helper | 32 | DFSORT Application Programming Guide: OUTFIL control statements (z/OS 3.1) |
| Mainframe Migration Checker | 23 | The site's own record decoder rules, as recorded in docs/FACTS.md |
| Why was I denied (RACF) | 22 | z/OS Security Server RACF Messages: ICH408I RACF Security Administrator's Guide: Authorization checking sequence RACF: Access authority for data sets |
| Test data masker | 19 | Mainframe KIT's own code page tables (A-Z, a-z and 0-9 share byte values across the offered code pages), checked by tests/unit/mask.test.ts Same encodings and signs as the packed decimal calculator (docs/FACTS.md) Keyed HMAC-SHA256 (Web Crypto): design note stated on the page |
| Compare tools | 17 | The site's own copybook viewer rules, as recorded in docs/FACTS.md |
| Record decoder | 11 | IBM z/Architecture decimal format (packed and zoned signs), as recorded in docs/FACTS.md EBCDIC code page tables: Python standard codecs (IBM tables) and the ebcdic package, as recorded in docs/FACTS.md Enterprise COBOL storage rules for binary and COMP-3 sizes, as recorded in docs/FACTS.md |
| Test data generator | 10 | The site's own copybook viewer and record decoder rules, as recorded in docs/FACTS.md |
| File health | 9 | IBM z/Architecture decimal format (packed and zoned signs), as recorded in docs/FACTS.md Enterprise COBOL storage rules for binary and COMP-3 sizes, as recorded in docs/FACTS.md |
| Copybook viewer | 5 | Enterprise COBOL storage rules (PIC, COMP, COMP-3, OCCURS, REDEFINES), as recorded in docs/FACTS.md IBM Enterprise COBOL for z/OS 6.5.0, Language Reference: Slack bytes within records IBM Enterprise COBOL 6.4 Language Reference: Computational items IBM Enterprise COBOL for z/OS 6.5.0, Language Reference: Computational items IBM Enterprise COBOL for z/OS 6.5.0, Language Reference: SIGN clause IBM Enterprise COBOL for z/OS 6.5.0, Programming Guide: CODEPAGE IBM Enterprise COBOL for z/OS 6.5.0, Language Reference: REDEFINES clause IBM Enterprise COBOL for z/OS 6.5.0, Language Reference: OCCURS DEPENDING ON clause |
| EBCDIC converter | 5 | EBCDIC code pages 037, 500, 273, 285, 1140, 1148 (Python standard codecs, IBM tables) and 1047 (the ebcdic package), as recorded in docs/FACTS.md |
| Job log reader | 5 | Code pages on this site (src/data/codes), each with its own IBM source |
| Block size calculator | 4 | IBM z/OS 3.2.0 DFSMS Using Data Sets, Basic access methods track capacity (3390 track capacity without keys, 27,998 most efficient block, cylinder = 15 tracks; page updated 29 Jul 2026, checked 15 Nov 2026) IBM z/OS 3.2.0 DFSMS Macro Instructions for Data Sets, Direct access storage devices (3390: 56,664 bytes per track, 15 tracks per cylinder, 27,998 most efficient block; page updated 24 Jun 2026, checked 15 Nov 2026) |
| Date converter | 4 | z/OS TIME macro (DATETYPE=YYDDD), as recorded in docs/FACTS.md Language Environment CEEDAYS definition (Lilian day 1), as recorded in docs/FACTS.md z/Architecture TOD clock; the value for 1 January 1970, X'7D91048BCA000000', is cross-checked by calculation in the tests (docs/FACTS.md) |
| Packed decimal calculator | 4 | IBM z/Architecture decimal format; Mainframe Path S0C7 page, as recorded in docs/FACTS.md Enterprise COBOL storage rules (binary sizes, COMP-3 bytes), as recorded in docs/FACTS.md |
| JCL generator | 2 | z/OS MVS JCL Reference and the z/OS utility references (IEFBR14, IDCAMS, IEBGENER, IEBCOPY); no page-level addresses are recorded in docs/FACTS.md |
| Site, release, privacy and shared checks | 440 | Pages, links, the security policy, release rules and shared code. No single IBM page. |
Speed, accessibility and privacy scans
Deep scan of v1.29.5 on 22 Nov 2026, in Chromium: every page at phone, tablet and desktop width in light and dark, every button on every tool, reflow at 320 px, and the privacy checks. It found nothing. The full test run (unit, build, search, browser and MCP checks) passed. Firefox and WebKit were covered by the live scan below. Real phones and real Safari hardware were not tested.
| VERSION | SCANNED | PAGE LOADS | BUTTONS | REFLOW CHECKS | FINDINGS | HOW |
|---|---|---|---|---|---|---|
| v1.29.5 | 22 Nov 2026 | 1585 | 464 | 250 | 0 | Chromium (automated, Playwright); from deepcheck-pages.mjs and deepcheck-interact.mjs, final run |
| v1.29.3 | 21 Nov 2026 | 1585 | 464 | 250 | 0 | Chromium (automated, Playwright); from deepcheck-pages.mjs and deepcheck-interact.mjs, final run |
| v1.29.1 | 21 Nov 2026 | 1585 | 396 | 250 | 0 | Chromium (automated, Playwright); from deepcheck-pages.mjs and deepcheck-interact.mjs, final run |
| v1.28.0 | date not recorded in the repository | 605 | 356 | 54 | 0 | Chromium (automated, Playwright); from CHANGELOG.md, v1.28.0 entry |
The deep scan loads every page at phone, tablet and desktop width in light and dark, presses every button on every tool, and reports sideways scrolling, script errors, requests to other sites, missing labels or alt text, small tap targets and small text. Page weight and speed figures are not part of it, so none are shown.
Cross-browser scan of the live site on 21 Nov 2026 (version 1.29.2): Chromium, Firefox and WebKit (the engine behind Safari), 246 pages, 1,230 page views per engine at phone, tablet and desktop width in light and dark, with the same checks as the deep scan. It reported no findings. Real Safari on a Mac or iPhone and real phones were not tested.
Expert scan of the live site on 22 Nov 2026 (version 1.29.3, then 1.29.4), by hand in a browser: all 22 tools with expert inputs and known answers, the error code pages, cheat sheets, guides and static pages, at phone, tablet and desktop width, light and dark. It found four real faults (two SQLCODE labels, a DFSORT message, a missing visible JCL note, small tap targets), fixed in v1.29.4, and one weak search, fixed in v1.29.5. Real phones and real Safari hardware were not tested.
Not tested
- Real phones
- Real Safari (WebKit is only emulated, and only when the live scan has run)
- Firefox, unless the live scan has run
- Screen readers; only automated checks for labels, alt text and contrast run
See also How it works and why it is safe.