Learn it on Mainframe Path. Do it with Mainframe KIT.Learn on Mainframe Path ▸
Mainframe KIT ● Nothing leaves this tab

AEID

EOF condition not handledCICS ABEND · CHECKED 2026-11-14
Checked against IBM documentation

A command raised EOF and the program had no RESP, NOHANDLE or HANDLE CONDITION for it, so CICS ended the task with abend AEID.

QUICK ANSWER

A command raised EOF and the program had no RESP, NOHANDLE or HANDLE CONDITION for it, so CICS ended the task with abend AEID.

LIKELY CAUSES, IN THE ORDER OF THIS ENTRY

  1. A command raised EOF and had neither a RESP nor a NOHANDLE option.
  2. No EXEC CICS HANDLE CONDITION for EOF was active when the command ran.

CHECKED 14 Nov 2026 IBM: AEID (CICS Transaction Server for z/OS 6.x) · AEIA abend (CICS Transaction Server for z/OS 6.x)

MOST LIKELY

A command raised EOF and had neither a RESP nor a NOHANDLE option.

FIRST CHECK

Change the program so the condition does not occur.

TRY IT ▸

Site search

What it means

The EXEC interface program (DFHEIP) issues AEID when EOF was raised on a command that has no RESP or NOHANDLE option, or the program has not run HANDLE CONDITION for it. CICS then takes the default system action, which is normally to abend the transaction.

The transaction is ended with a CICS transaction dump. IBM describes the whole group of AEIx abends together under AEIA.

Typical causes

  • A command raised EOF and had neither a RESP nor a NOHANDLE option.
  • No EXEC CICS HANDLE CONDITION for EOF was active when the command ran.

How to fix it

  1. Change the program so the condition does not occur.
  2. Add the RESP option to the command and test the response.
  3. Or code HANDLE CONDITION for the condition and decide what the program should do then.
  4. Use EIBRESP2 or EIBRCODE from the EIB to help find the cause.
  5. The function code of the failing command is at offset X'1B' in the EIB, EIBRCODE at X'1D', EIBRESP at X'4C' and EIBRESP2 at X'50'; use them in the dump to identify the command.